When the ambient temperature is 25 ±2ºC and the emissivity (ε) is 1,
0 ~ 300ºC:
bigger value of either of ±1% of the
measured value ±1dgt or ±2ºC ±1dgt.
0 ~ -30ºC:
|±3ºC ±1dgt
below -30ºC:
|±5ºC ±1dgt
Repeatability
within 1ºC ±1dgt
Response
1 sec (90% response)
Measuring Diameter
(45mm/500mm(Optical sensitivity: 90%)
Collimation
Before shipment: 0.95. The value can be altered between 0.8and 1.0 with the slide switch at the lower part of the battery compartment
(by 0.05 steps).
Laser beam (650nm 1mW JIS class2) specifies the center.
Water-Proof Property
IP67
Auto Power Off
If no key is pressed for 30 seconds, the power is shut off automatically.
Shock Proof Property
This instrument or its function/performance will not be damaged even if it is dropped on the p tile floor from 1 meter high.
Operating Temperature
0 ~ 50ºC
Operating Humidity
90% rH and below (no condensation)
Storage Temperature
-20 ~ 55ºC (no condensation)
(Note): In the case of longterm storage, the batteries should be removed.
Battery
2 AAA alkaline cell batteries
Battery Life
Approximately 10 hours for continuous use
Housing material
ABS (antibacterial)
Dimension
120 × 60 × 54mm (Maximum value for each direction)